电动卷闸门在使用过程中需要调整哪些?

来源: 日期:2024-02-27 发布人:

电动卷闸门产品调整主要分三部分进行:

The adjustment of electric rolling gate products is mainly carried out in three parts:

机械部分调整

Mechanical part adjustment

(1)限位调整,卷闸门安装结束后,对门产品的机械部分进行调整,两步降落的卷闸门一步降位应在距地面1.8m位置。

(1) Limit adjustment: After the installation of the rolling gate is completed, the mechanical part of the door product should be adjusted. The two-step lowering of the rolling gate should be at a height of 1.8m from the ground.

20230121055037949.jpg

(2)速放装置试验,通过手动速放装置拉链下放防火卷闸门,帘桓下降顺畅,速度均匀,一步停降到底。

(2) Quick release device test, using manual quick release device zipper to lower the fire shutter, the curtain can descend smoothly and at a uniform speed, stopping and descending to the bottom in one step.

(3)提升装置试验,通过手动拉链拉起防火卷闸门,拉起全程应顺利,停止后防火卷闸门应当靠其自重下降到底。

(3) The lifting device test involves manually pulling up the fire shutter with a zipper. The entire process should be smooth, and after stopping, the fire shutter should be lowered to the bottom by its own weight.

电动部分调整在电动卷闸门两侧安装的手动按钮来对门产品进行升、停、降,防火系列的卷闸门可以任意的通过停止按钮来停止门产品。

The manual buttons installed on both sides of the electric roller shutter are used for adjusting the electric part to lift, stop, and lower the door product. The fireproof series roller shutter can be stopped by the stop button at will.

自动功能调整

Automatic function adjustment

电动卷闸门产品的自动控制方式分有源和无源启动两种:无源启动:门产品可以利用短路线分别短接中限位和下限为的远程控制,观察期下落是否顺畅,悬停位置是否准确,用万用表实测中限位和下限位电信号无源回答端子是否导通。有源启动:门在自动方式调试需要24V电源来供电启动卷闸门系列产品,观察下落是否顺畅,悬停位置是否准确,用万用表实测中限位和下限位的电信号的无源回答端子观察其是否导通。

The automatic control methods of electric rolling gate products are divided into active and passive start: passive start: The door product can use a short circuit to respectively short circuit the middle limit and lower limit for remote control, observe whether the falling period is smooth, whether the hovering position is accurate, and use a multimeter to measure the electrical signals of the middle limit and lower limit to passively answer whether the terminals are conductive. Active start: The automatic debugging of the door requires a 24V power supply to start the rolling gate series products. Observe whether the falling is smooth and the hovering position is accurate. Use a multimeter to measure the passive response terminals of the electrical signals in the middle and lower limits and observe whether they are conductive.

阅读/ Recommended reading

1.急停按钮1. Emergency stop button按下紧急停止按钮时,一对触点断开窗帘所需的机电设备,另一对触点进入PLC,断开PLC控制的机电设备的启动电路。When ...